Blue Max Stainless Wire

Diameters / Packaging

Diameters
33 lb (15 kg) Steel Spool
0.035 in (0.9 mm) MG276035667
0.045 in (1.1 mm) MG276045667
1/16 in (1.6 mm) MG276062667

Techalloy® 276

MIG (GMAW)

CLASSIFICATIONS:
AWS A5.14 : ERNiCrMo-4

TECHALLOY® 276 is designed for use with low carbon, nickel-chromium-molybdenum filler metal can also be used for dissimilar welding between nickel base alloys and stainless steels for cladding used in LNG applications.

DETAILS

TECHALLOY® 276 is ideal for materials of similar composition due to high molybdenum content due to high molybdenum content, this alloy offers excellent resistance to stress corrosion cracking, pitting and crevice corrosion.

Features

  • Used for welding materials of similar composition
  • Due to high molybdenum content, this alloy offers excellent resistance to stress corrosion cracking, pitting and crevice corrosion
  • Q2 Lot® - Certificate showing actual wire composition available online
  • Q2 Lot® - Certificate showing actual wire composition available online

Typical Applications

  • Low carbon, nickel-chromium-molybdenum filler metal can also be used for dissimilar welding between nickel base alloys and stainless steels for cladding
  • Used in LNG applications
  • Maintenance and Repair Welding

Welding Positions

  • All

Shielding Gas

  • MIG 75% Ar / 25% He

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.14 ERNiCrMo-4
CWB AWS A5.14 ERNiCrMo-4

WIRE COMPOSITION

Classification %C %Co %Cr %Cu %Fe %Mn %Mo %Ni %P %S %Si %V %W
ERNiCrMo-4 Requirement 0.02 max. 2.5 max. 14.5 - 16.5 0.50 max. 4.0 - 7.0 1.0 max. 15.0 - 17.0 Remainder 0.04 max. 0.03 max. 0.08 max. 0.35 max. 3.0 - 4.5
Typical Result 0.003 max. 0.0 max. 15.8 0.02 5.6 0.5 15.6 0.003 max. 0.003 max. 0.03 0.00 max. 3.7 59

TYPICAL OPERATING PROCEDURES

Diameter Shielding Gas Polarity Voltage
volts
Approx. Current
amps
.035" (0.9 mm) 75% Ar, 25% He DC+ 26-29 150-190
.045" (1.1 mm) 75% Ar, 25% He DC+ 28-32 180-220
1/16" (1.6 mm) 75% Ar, 25% He DC+ 29-33 200-250